ABSTRACT

For registration of generic and similar drugs, it is necessary to carry out pharmaceutical equivalence (PE) tests and pharmaceutical bioequivalence (PB). To carry out these tests, duly qualified research centers are contracted, which need to be monitored by the sponsor who is legally responsible for the activities. To this end, it is the recommendation of the Document of the Americas, periodic monitoring to verify compliance with quality requirements, Standard Operating Procedures, Good Clinical Practices (GCP), Good Laboratory Practices (GLP), of the applicable regulatory framework, as well as of compliance with the study protocol. Thus, monitoring is a methodical and documented process to evaluate the degree of adhesion of the center to the planned design for the evaluation of the formulations. To this end, the implementation of a standardized and easily completed guideline is a very important tool to guarantee a consistent evaluation and maintain the organizational memory of the evaluated items by monitors designated by the sponsor, contributing to the constant improvement of the contracted centers and supporting traceability of the studies. This work provided a systemic view of the evidence process related mainly to pharmaceutical bioequivalence, with the monitoring guideline summarizing the items of greatest relevance to be verified.


Para registro de medicamentos genéricos e similares, é necessária a realização de testes de equivalência farmacêutica (EF) e bioequivalência farmacêutica (BF). Para a realização desses testes, são contratados centros de pesquisa devidamente habilitados, que precisam ser monitorados pelo patrocinador legalmente responsável pelas atividades. Há também a recomendação do Documento das Américas de realizar monitoramentos periódicos para verificar o cumprimento dos requisitos de qualidade, Procedimentos Operacionais Padrão, Boas Práticas Clínicas (BPC), Boas Práticas de Laboratório (BPL), de marco regulatório aplicável, bem como de cumprimento do protocolo do estudo. Assim, o monitoramento é um processo metódico e documentado para avaliar o grau de adesão do centro ao desenho planejado para a avaliação das formulações. Para tanto, a implantação de uma diretriz padronizada e de fácil preenchimento é uma ferramenta muito importante para garantir uma avaliação consistente e manter a memória organizacional dos itens avaliados por monitores designados pelo patrocinador, contribuindo para a melhoria constante dos centros contratados e apoiando rastreabilidade dos estudos. Este artigo forneceu uma visão sistêmica do processo de evidência relacionado principalmente à bioequivalência farmacêutica, com a diretriz de monitoramento resumindo os itens de maior relevância a serem verificados.


Para el registro de medicamentos genéricos y similares, es necesario realizar pruebas de equivalencia farmacéutica (EP) y de bioequivalencia farmacéutica (PB). Para llevar a cabo estas pruebas se contratan centros de investigación debidamente cualificados, que deben ser supervisados por el promotor, que es el responsable legal de las actividades. Para ello, es la recomendación del Documento de las Américas, el monitoreo periódico para verificar el cumplimiento de los requisitos de calidad, los Procedimientos Operativos Estándar, las Buenas Prácticas Clínicas (BPC), las Buenas Prácticas de Laboratorio (BPL), del marco regulatorio aplicable, así como del cumplimiento del protocolo del estudio. Así, la monitorización es un proceso metódico y documentado para evaluar el grado de adhesión del centro al diseño previsto para la evaluación de las formulaciones. Para ello, la implantación de una pauta estandarizada y de fácil cumplimentación es una herramienta muy importante para garantizar una evaluación consistente y mantener la memoria organizativa de los elementos evaluados por parte de los monitores designados por el promotor, contribuyendo a la mejora constante de los centros contratados y apoyando la trazabilidad de los estudios. Este trabajo proporcionó una visión sistémica del proceso de evidencia relacionado principalmente con la bioequivalencia farmacéutica, con la pauta de monitoreo que resume los ítems de mayor relevancia a ser verificados.


Subject(s)
Biological Availability , Therapeutic Equivalency , Practice Guideline , Pharmaceutical Preparations , Drugs, Generic , Practice Guidelines as Topic , Brazilian Health Surveillance Agency , Drug Development , Regulatory Frameworks for Health
2.
Rev. cuba. farm ; 49(4)oct.-dic. 2015. ilus
Article in Spanish | LILACS, CUMED | ID: lil-780752

ABSTRACT

El Plan Estratégico Nacional para la Prevención y Control de las ITS/VIH/sida, 2014-2018 en Cuba establece un grupo de acciones entre las que se encuentra la estandarización y optimización de esquemas de terapia antirretroviral, adecuación del inicio del tratamiento a las recientes recomendaciones de la Organización Mundial de la Salud, mejorar la calidad de la atención, la adherencia y la reducción del costo de los medicamentos. Para cumplir estas tareas se prevé introducir en el Cuadro Básico de Medicamentos algunos antirretrovirales genéricos cubanos para incrementar las posibles combinaciones de Terapia Antirretroviral de Alta Eficacia a disposición de los pacientes que viven con el virus de la inmunodeficiencia humana y sustituir importaciones. Se realizó una revisión bibliográfica exhaustiva para la actualización de la comunidad médica y científica; se examinaron las principales características del abacavir: propiedades químico-físicas del principio activo, sus presentaciones comerciales, mecanismo de acción, farmacocinética y resistencia, reacciones adversas e interacciones, aplicaciones terapéuticas, dosificaciones, ajustes de dosis y seguridad en el embarazo. Para ello se consultaron un total de 58 artículos que incluyeron revisiones bibliográficas, trabajos originales, fichas técnicas, libros, conferencias y reportes. El abacavir es un antirretroviral relativamente nuevo y ampliamente recomendado por las guías de tratamiento por su efectividad demostrada(AU)


The National Strategic Plan for the Prevention and Control of the IST/HIV/ aids, 2014-2018 in Cuba establishes a group of actions such as the standardization and optimization of antiretroviral therapy schedules, adaptation of the beginning of the treatment to the recent recommendations of the World Health Organization, the improvement of the quality of care, the adherence to and the reduction of the cost of medications. For the purpose of complying with these tasks, it is anticipated to introduce in the basic drug listing some Cuban generic antiretroviral drugs to increase the possible combinations of the Highly Active Antiretroviral Therapy available for patients who live with the human immunodeficiency virus and to reduce imports. An exhaustive literature review was made for the update of the medical and scientific community knowledge. This article analyzed the main characteristics of abacavir such as chemical-physical properties of the active principle, their commercial presentations, mechanism of action, pharmacokinetics and resistance, adverse reactions and interactions, therapeutic applications, dosages, dose adjustments and safety at pregnancy. To this end, a total of 58 articles were consulted including literature reviews, original papers, technical records, books, lectures and reports. Abacavir is a relatively new antiretroviral, widely recommended by treatment guidelines on account of its proven effectiveness(AU)


Subject(s)
Humans , Acquired Immunodeficiency Syndrome/prevention & control , HIV/drug effects , Anti-Retroviral Agents/therapeutic use , Cuba , Antiretroviral Therapy, Highly Active
3.
Article in English | LILACS | ID: lil-658491

ABSTRACT

In Brazil, in order for a pharmaceutical company to register a drug form as generic or ?similar? with the Brazilian food and drug agency (Anvisa), it must be proved bioequivalent to its innovatory branded form (reference drug). This requires comparative trials, carried out in conformity with official compendia (Brazilian Pharmacopeia or another officially recognized code). Additionally, according to the Anvisa resolution RDC 31/2010, the dissolution profile of the drug must be tested and compared with that of the branded reference, as a benchmark of quality. The aim of this study was to assess the quality of 500 mg sodium metamizole (dipyrone) tablets produced by seven different laboratories in Brazil: three generic drugs (G1, G2, G3), three (branded) similar drugs (S1, S2, S3) and their reference branded product (Novalgina®, Sanofi-Aventis, drug R). All tests were carried out by methods specified in the Brazilian Pharmacopeia 4th edition (Farmacopeia Brasileira IV). The following tests were performed: uniformity of mass, friability, disintegration time, hardness, assay, uniformity of dosage units, salicylic acid limit assay, dissolution and identification. The dissolution profile was also recorded, as recommended in RDC 31/2010. Whereas every sample was approved in all the Farmacopeia Brasileira IV tests, the results in the dissolution profile test showed that four of the test drugs (G1, G2, S1 and S2) were not pharmaceutically equivalent to drug R. Thus, only drugs G3 and S3 showed dissolution profiles similar to that of drug R and the other four drugs could not be considered equivalent to it and were not approved.


No Brasil, para que uma indústria farmacêutica registre um produto como genérico ou similar, o medicamento deve ser bioequivalente a seu medicamento de referência. Isto requer a realização de estudos comparativos, seguindo um compêndio oficial (Farmacopeia Brasileira ou outra reconhecida oficialmente). Além disso, de acordo com a RDC 31/2010, também deve ser realizado o estudo do perfil de dissolução em relação ao seu medicamento de referência. Este estudo teve como objetivo avaliar a qualidade de comprimidos de metamizol sódico (ou dipirona) com teor de 500mg produzidos por sete diferentes laboratórios brasileiros: três medicamentos genéricos (G1, G2, G3), três similares (S1, S2, S3) e o medicamento de referência (Novalgina®, Sanofi-Aventis, R). Todos os testes seguiram os métodos descritos na Farmacopeia Brasileira IV. Os seguintes ensaios foram realizados: uniformidade de massa, friabilidade, tempo de desintegração, dureza, doseamento, uniformidade de doses unitárias, ensaio limite de ácido salicílico e identificação. O perfil de dissolução foi realizado como recomendado pela RDC 31/2010. Apesar das amostras terem sido aprovadas em todos os ensaios farmacopéicos, os resultados do perfil de dissolução indicaram que quatro medicamentos (G1, G2, S1 e S2) não são equivalentes farmacêuticos de R. Apenas G3 e S3 mostraram perfis similares a R. Assim, quatro medicamentos foram reprovados.


Subject(s)
Dipyrone , Drug Evaluation , Drugs, Generic/pharmacokinetics , Similar Drugs , Solubility , Brazil
4.
Ciênc. Saúde Colet. (Impr.) ; 17(1): 79-87, jan. 2012. tab
Article in Portuguese | LILACS | ID: lil-610661

ABSTRACT

Embora os genéricos tenham sido introduzidos no país para oferecer alternativa mais acessível aos medicamentos de referência, representam apenas 14 por cento das vendas em unidades no conjunto do mercado farmacêutico. O objetivo deste trabalho foi pesquisar o nível de conhecimento e o grau de utilização de genéricos em residentes do município de Tubarão, SC. Para isso, realizou-se um estudo transversal com uma amostra de 234 entrevistados, estratificada por bairro. Quanto ao grau de utilização, a maioria dos entrevistados já havia utilizado genéricos, e metade possuía pelo menos um exemplar dessa opção em casa. Para verificar o conhecimento sobre os diferentes tipos de medicamentos, realizou-se um teste de identificação de figuras de embalagens representativas das versões genérico, de referência e similar do paracetamol e do atenolol, 91,0 por cento dos sujeitos identificaram corretamente todas as figuras. Ser de classe econômica mais elevada, já ter utilizado medicamento genérico, acreditar que o genérico tem o mesmo efeito que o medicamento de referência, encontrar medicamentos genéricos nas farmácias com facilidade e costumar comprar o genérico foram fatores associados positivamente com a identificação correta.


Although generic medication has been introduced in the country to offer an accessible alternative to brand-name medication, it represents only 14 percent of sales in number of units within the pharmaceutical market. The aim of this work was to research the level of awareness and the use of generic products among residents of the municipality of Tubarão, State of Santa Catarina, Brazil. A transversal study was carried out with a sample of 234 interviewees, distributed among municipal areas. With regard to use, the majority of those interviewed had used generic medication, and half of them had at least one such product in their home. To verify awareness of different types of medication, pictures with the generic, brand name and similar packaging for paracetamol and atenolol were shown and 91 percent were able to identify all products correctly. To be of higher economic standing, already having used generic products, believing that the generic medication has the same effect as the brand name medication, finding generic products in drugstores easily and being accustomed to buy generic products, were factors that were positively associated with the correct identification.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Drugs, Generic/therapeutic use , Health Knowledge, Attitudes, Practice , Brazil , Cross-Sectional Studies
5.
Braz. j. pharm. sci ; 46(3): 509-513, July-Sept. 2010. tab
Article in English | LILACS | ID: lil-564917

ABSTRACT

The aim of this study was to evaluate the quality of five different solid formulations of carbamazepine. The reference formulation was Tegretol® 200.00 mg (Novartis) and the others were: generic formulation of carbamazepine 200.00 mg (National Industry), similar formulation of carbamazepine 200.00 mg (National Industry), and two formulations of carbamazepine 200.00 mg acquired from two different compounding pharmacies. The latter consisted of capsules obtained in Natal, the capital city of the Brazilian State of Rio Grande do Norte. The quality of samples was evaluated through physical and physical-chemical tests, including: weight, diameter, thickness, content, dissolution, disintegration, hardness, friability and moisture. The results of friability analysis showed that all formulations met Brazilian and United States Pharmacopeia (USP) specifications. In spite of having a higher hardness compared to the reference, the generic formulation had a lower disintegration time. This could be associated to the presence of crospovidone in its formulation. Results of this study showed that all formulations had dissolutions which were in accordance with Brazilian Pharmacopoeia specifications, and quality control tests. An exception was found for the similar formulation, which had a hardness parameter that exceeded the USP standard. However, this difference was not significant given the similar formulation's satisfactory disintegration time.


O objetivo desse trabalho foi avaliar a qualidade de cinco formulações de carbamazepina na dosagem de 200,00 mg: medicamento referência Tegretol® (Novartis), medicamento genérico (indústria nacional), medicamento similar (indústria nacional) e cápsulas do mesmo medicamento obtidas de duas farmácias de manipulação da cidade do Natal, RN. Os ensaios realizados foram: peso médio, diâmetro, espessura, teor, dissolução, desintegração, dureza, friabilidade e umidade. Foi observado que nenhuma das amostras analisadas apresentou friabilidade superior ao limite máximo determinado pela Farmacopéia Americana (1,5 por cento). O medicamento genérico, apesar de apresentar dureza superior em relação ao medicamento de referência, desintegrou em menor tempo, o que pode estar relacionado à crospovidona presente na formulação. As amostras analisadas atenderam às especificações da Farmacopéia Brasileira no que diz respeito à dissolução. Em geral, os resultados das amostras A, B, C, D e E foram considerados satisfatórios uma vez que atenderam as especificações farmacopéicas. Embora a apresentação similar não tenha atendido ao padrão USP no que diz respeito à dureza, esse dado não se mostrou significativo, uma vez que o tempo de desintegração foi satisfatório.


Subject(s)
Carbamazepine/pharmacology , Diagnosis/methods , Chemistry, Pharmaceutical , Drugs, Generic/therapeutic use
6.
Article in Portuguese | LILACS | ID: lil-560257

ABSTRACT

Com o avanço da tecnologia e das pesquisas envolvendo liberação de fármacos, modernização de testes e maior ênfase da previsibilidade de efeitos terapêuticos por meio dos testes in vitro, os testes de dissolução e os estudos de perfis de dissolução têm ganhado cada vez mais importância. Apesar de terem sido introduzidos inicialmente como uma forma de caracterizar o perfil de liberação de fármacos pouco solúveis, atualmente os testes de dissolução fazem parte das monografias de quase todas as formas farmacêuticas sólidas orais. Este trabalho teve como objetivo estudar o perfil de dissolução (porcentagem de fármaco dissolvido versus tempo) dos medicamentos de referência, genérico e similar contendo cefalexina 500 mg na forma farmacêutica de cápsulas. Foram analisadas três especialidades farmacêuticas (referência, genérico e similar), os quais foram submetidos ao teste de dissolução e perfil de dissolução in vitro. Os resultados obtidos no teste de dissolução permitem concluir que as amostras encontraram-se de acordo com as especificações e o perfil de dissolução deste medicamento, nesta forma farmacêutica, é considerado de dissolução rápida (85% de fármaco dissolvido em 15 minutos). Portanto, existe uma grande semelhança entre as curvas obtidas, o que sugere que se trata de equivalentes farmacêuticos.


With recent advances in technology and research into drug delivery, the modernization of tests and greater emphasis on the predictability of therapeutic effect by means of in vitro tests, the dissolution test and the study of dissolution profiles are gaining more and more importance. Though introduced initially as a way of characterizing the release profile of poorly soluble drugs, dissolution tests are currently part of pharmacopoeial monographs on almost all the oral solid pharmaceutical forms. The objective of this study was to determine the dissolution profile (percent drug dissolved versus time) of the pioneer brand, generic and similar pharmaceutical capsules containing 500mg cephalexin. Three pharmaceutical brands (reference, generic and similar) were subjected to the dissolution test and in vitro dissolution profiles were recorded. From the results of the dissolution test, it was concluded that the samples met the acceptance criterion, as no difference was observed in the percentage of the drug dissolved in a standard time. The dissolution profile indicated that this medicine, in this pharmaceutical form, dissolves readily (85% of the drug dissolved in 15 minutes) and the curves showed great similarity, suggesting that the 3 brands are pharmaceutically equivalent.


Subject(s)
Humans , Capsules , Cephalexin/pharmacokinetics , Drugs, Generic , Reference Drugs , Similar Drugs
7.
Braz. j. vet. res. anim. sci ; 45(supl): 5-19, 2008. graf, tab
Article in English | LILACS | ID: lil-533232

ABSTRACT

Bioequivalence (BE) studies are scientific methods that allow comparison of different medicinal products containing the same active substance, or different batches of the same medicinal products or, ina broad sense, different routes of administration of the same product. Actually, legislation on generic drugs and bioequivalence only exist in Brazil for drugs intended for human purposes. In the field of Veterinary Medicine, BE is being used in many countries as part of the necessary requirements for registration of animal health products,i.e., to provide efficacy and safety animal data and to allow consumers safety; indeed, they also assure the quality of the food derived from treated animals. The present manuscript was designed to review and discuss BE; for that, it was divided into three major parts: 1-understanding bioequivalence: importance of BE studies for animal and human health; 2- type of BE studies included; 3- general consideration on experimental design involved o BE studies.


Os estudos de Bioequivalência (BE) são utilizados para a comparação de diferentes produtos farmacêuticos que contêm o mesmo princípio ativo, de diferentes lotes de um mesmo produto ou, ainda e de uma maneira ampla, de diferentes vias deadministração de um mesmo medicamento. No Brasil dos dias de hoje, encontramos legislações sobre medicamentos genéricos e bioequivalência apenas na área de Medicina Humana. No campo da Medicina Veterinária, os testes de BE têm sido considerados,em muitos países, como requerimentos necessários para o registro de produtos destinados aos animais visto que eles asseguram, ao mesmo tempo, a eficácia do produto, a saúde dos animais tratados e a qualidade dos alimentos provenientes desses animais. O presente trabalho faz uma revisão crítica sobre BE. Para tanto, o assunto foi dividido em três grandes partes: 1- Entendendo a bioequivalência: importância de estudos de BE para a saúde animal e humana; 2- tipos de estudos de BE; 3- considerações gerais sobre delineamentos experimentais que envolvam estudos de bioequivalência.


Subject(s)
Drugs, Generic/analysis , Drugs, Generic/adverse effects , Pharmacokinetics , Reference Drugs , Therapeutic Equivalency
8.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 43(3): 413-419, jul.-set. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-468148

ABSTRACT

A glibenclamida (GLIB) ou gliburida, é um hipoglicemiante oral de segunda geração, da classe das sulfoniluréias, usado sob a forma de comprimidos para tratamento do diabetes mellitus. Variações no tratamento podem ocorrer, devido à baixa solubilidade do fármaco em comprimidos. A comparação de várias formulações de comprimidos piloto com comprimidos do medicamento referência (Daonil®, glibenclamida 5 mg comprimidos, Aventis Pharma Ltda.) foi avaliada por meio do desenvolvimento de um teste de dissolução sem adição de solventes orgânicos ou tensoativos no meio, que mostrou ser discriminativo para as diferentes formulações farmacêuticas propostas. A quantificação de GLIB foi realizada por meio de cromatografia líquida de alta eficiência em fase reversa (CLAE-FR), método previamente validado. A partir de vários ensaios de perfil de dissolução testados comparativamente àquele de comprimidos do medicamento referência, verificou-se o potencial de determinada formulação proposta (f1 4,04 and f2 69,35) como candidata a medicamento genérico no mercado brasileiro.


Glibenclamide (GLIB) or glyburide, a second-generation hypoglycemic agent is used per oral as tablets for the treatment of diabetes mellitus. Much variabilility in the treatment may occur because of the low drug aqueous solubility in tablets dosage forms. This work reports the comparison of several pilot formulation batches with the commercial reference drug dosage form (Daonil®, glibenclamide 5 mg per tablet, Aventis Pharma Ltda.). A feasible dissolution test, developed with no use of organic solvents or surfactants in the medium, showed to be discriminative regarding to different formulations tested. GLIB quantitation was performed by a previously validated reverse-phase high performance liquid chromatography (RP-HPLC). Among several dissolution profiles compared with that of a commercial reference, a potential for a generic candidate was evident (f1 4.04 and f2 69.35) for a proposed solid dosage formulation in the Brazilian market.


Subject(s)
Drugs, Generic , Diabetes Mellitus/metabolism , Glyburide/pharmacokinetics , Dissolution , Solubility
9.
São Paulo; s.n; 2005. 275 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-425838

ABSTRACT

Lamivudina (3TC) e zidovudina (ZDV) são inibidores nucleosídeos da transcriptase reversa utilizados na terapêutica anti-HIV. Para avaliar a equivalência farmacêutica entre um medicamento teste contendo esta associação e o referência, foi desenvolvido um método para determinação cromatográfica simultânea de 3TC e ZDV em comprimidos. O método empregou coluna C8 Shim-pack® (150 x 4,6 mm, 5 um), pré-coluna C18 Phenomenex® (50 x 4,6 mm 5 um), água e metanol 60:40 (v:v) como fase móvel e detecção a 266nm. Este mostrou-se específico, com linearidade entre 45 a 5000 ng/mL, precisão demonstrada por CV por cento inferior a 5 por cento, exatidão entre 90,0 e 110,0 por cento com recuperação superior a 90 por cento para ambos os fármacos...


Lamivudine (3TC) and zidovudine (ZDV) are the nucleoside reverse transcriptase inhibitors, They are used in combinations of antiretroviral therapy. The switchability between one test product and reference could be proved if they are pharmaceutically equivalents and bioequivalents. This research beginning with development and validation of chromatographic method to 3TC and ZDV simultaneous determination in tablet. The HPLC system were used to assay and 266nm wavelength ultraviolet detector. Separation was performed using a C8 column (150 x 4,6 mm, 5 µm) Shim-pack®protected by a C18 column (50 x 4,6 mm, 5 µm) Phenomenex®. The mobile phase is composed of water and methanol 60:40 (v:v). This method was successfully applied to simultaneous determination to 3TC and ZDV without interference. It was validated over the range of 45 a 5000 ng/mL for both drugs with accurate from 90 to 110% and precision with variation lower than 5%. Extraction recoveries of the analytes were higher than 90%. The mean dissolution data about 3TC and ZDV were above than 85% in 30 minutes of dissolution test. The relative bioavailability between Biovir® (brand-name product) and Lamivudina + Zidovudina 150 + 300 mg (test product), was conducted for one direct quantitative, open and crossover study. The serial plasma sample of 3TC and ZDV collected after oral administration of brand-name product and test product, were analyzed using a validated high-performance liquid chromatography assay with UV detection in wavelength of 270 nm. The double liquid-liquid extraction was realized with additions of amonio acetat. A CLC-C8 (M) column (150 x 4,6 mm 5 µm) Shim-pack®and C18 column (50 x 4,6mm 5 µm) Phenomenex®, was eluted with two mobile phase in a linear gradient system at a flow-rate...


Subject(s)
HIV Seropositivity , Lamivudine , Zidovudine , Biological Availability , Biopharmaceutics , Chromatography, Liquid/methods , Permeability , Therapeutic Equivalency